Cell phone jammer has low environmental requirements

Are installed under the floor. 1) strong electric trunk tray selection 400 * 200mm galvanized tray. Bottom height of 0.3 m from the ground. 2) strong electrical tributary bridge use 100 * 100mm galvanized tray in the cabinet. Bottom height of 0.3 m from the ground. 3) building a network bridge selected 300 * 100mm galvanized bridge from the ceiling into the room hosts a dedicated channel. 4) backbone network bridge host room selection 500 * 100mm galvanized tray. Bottom height of 0.4 m from the ground. 5) branch network bridge host room selection 300 * 100mm galvanized tray.cell phone jammer has high reliability and good anti-collision performance. Bottom height of 0.4 m from the ground. 6) bridge outside the frame selected 200 * 100mm galvanized bridge outside the wiring from the ceiling into the room. 7) the strength of electrical bridge installation to avoid mutual interference. Distribution cable 1) room all made high-quality power distribution cables are used ZR-YJV flame retardant power cable. See materials list. Branch pipe from the bridge leads to wear protection. 2) room in the power distribution trunk cables are laid inside the tray. Grounding System 1) separate shield ground. 2) other types of grounding a common grounding. Room floor installation 40 * 4MM ground copper busbar, copper busbar and ground power distribution cabinet composed of rows of rooms equipotential ground bus.cell phone jammer has the complete machine shape.  The engine room of a variety of ground, such as security, the anti-static grounding and equipment enclosures, cabinets cabinet, metal components are all connected to the grounding wire equipotential ground bus. 3) room floor bracket 16MM composed of braided copper grounding grid spacing 1800 * 1800MM. 4) Each equipment cabinet leads to two 16MM woven copper, received equipotential ground bus. 5) The engine room of the ground wire or ground terminal provided by the building construction, requiring the building grounding resistance of grounding device is less than 1 ohm.cell phone jammer has low environmental requirements. Room distribution system construction phases 1) a power distribution system includes 2 UPS, 7 δΈͺ power distribution cabinets, counters and the first four columns corresponding distribution cables, power distribution equipment rack 60 slip, non-shielded room distribution, three precision air conditioning and power distribution cables VRV air conditioning, room lighting, power distribution systems, computer room grounding systems. 2) two power distribution system includes 2 UPS, 2 power distribution cabinets, two column headers and the corresponding distribution cables cabinet, equipment rack power distribution branch 30, 2 precision air-conditioning power distribution cables. 3) first and second content distribution system according to the project construction and site conditions determine the total demand.cell phone jammercan work for a long time in various conditions. Fifth, room layout: room layout: 1) required for each server rack server access switch cabinets for each of the laying of 10 six shielded cable, and configure the corresponding wiring devices, including six types of shielded twisted pair, TJ45 with stand, six shielded jumper, jumper Gigabit fiber. 2) optical storage system wiring. See BOQ. Six room environment monitoring system: room environment monitoring system: environmental monitoring system features 1) Power supply monitoring of room: The main room is the center of all the uninterruptible power supply (UPS) monitoring and management, real-time monitoring of operating data and power state, such as three-phase input voltage, current, power, the phase output voltage, current, power and other data, to support a variety of ways, such as abnormal color images, text and sound light, send text messages and other alerts.

No comments:

Post a Comment